ASFHB1000

SKU: ASFHB1000 Category:

Product Features

  • Ceramic brazing sealing technology; sealed chamber meets IP67 protection rating.
  • Hydrogen-filled chamber effectively prevents oxidation of internal metallic components.
  • 1000A continuous current carrying capacity
  • 1 set of bridge-type normally open (SPST-NO) contacts; non-polarized main contacts.
  • Widely applicable to construction machinery, energy storage systems (ESS), EV charging stations, and other electrical sectors.

Model Description

ASFHB1000

Main Technical Specifications

Parameters Specifications
Contact Form 1H (SPST-NO)
Rated Load Current 1000A
Min. Load (Resistive) 1A 12VDC
Max. Breaking Current 3000A (1000V DC; 50ms; 1 op)
Max. Switching Voltage 1500VDC
Contact Resistance (Initial) ≤0.2mΩ@1000A (Initial)
Overload Current Capability (Conductor size XX mm²; 85°C) 1000A cont. 1500A 200s
2000A 100s 3000A 16s

General Electrical Characteristics

Parameters Specifications
Insulation Resistance (Between Open Main Contacts) ≥1000MΩ(@1500VDC)
Insulation Resistance (Between Main Contacts and Coil) ≥1000MΩ(@1500VDC)
Insulation Resistance (Between Main and Auxiliary Contacts) ≥1000MΩ(@1500VDC)
Dielectric Withstanding Voltage (Between Open Main Contacts) ≥5000V AC (1min; leakage current ≤1mA)
Dielectric Withstanding Voltage (Between Main Contacts and Coil) ≥5000V AC (1min; leakage current ≤1mA)
Dielectric Withstanding Voltage (Between Main and Aux Contacts) ≥5000V AC (1min; leakage current ≤1mA)
Operate Time (At rated coil voltage, 23°C) ≤100ms
Release Time (At rated coil voltage, 23°C) ≤30ms

Auxiliary Contact Specifications

Parameters Specifications
Contact Form 1H(SPST-NO)
Rated Load 100mA 6V DC
Min. Load 3mA 6V DC
Contact Resistance ≤150mΩ@1A

Shock & Vibration Resistance

Parameters Specifications
Shock – Stability (Disconnected) 1/2 sine,11ms,20G
Shock – Stability (Closed state) 1/2 sine,11ms,20G
Shock – withstand 1/2 sine,6ms,50G
Random vibration 10Hz~2000Hz,57.9m/s²

Operating Conditions

Parameters Specifications
Ambient Temp -40℃~+85℃
Humidity 5%~85%RH

Endurance

Parameters Specifications
Electrical Endurance (Resistive) Making
100A/1000V DC 50 (ops)
Breaking
1000A/1000V DC 300 (ops)
1000A/1500V DC 200 (ops)
Mechanical Endurance 20W ops

Coil Characteristics (@23°C)

Rated Voltage V DC Max. Operating Voltage V DC Pick-up Voltage V DC Drop-out Voltage V DC Power Consumption W
12 16 ≤9 ≥1 Inrush:50
Holding:5
24 32 ≤18 ≥2 Inrush:50
Holding:5
24 63 ≤36 ≥4.8 Inrush:50
Holding:5

Current withstand curve

ASFHB1000

Notes:

1. Ambient temperature: 85°C; conductor cross-sectional area: ≥800 mm².

2. The upper temperature limit of the curve is 130°C, representing the maximum capacity for long-term cyclic operation.

3. In the event of short-term operation at currents ≥2000 A, there is a risk of the product components sticking (fusing) together; however, this will not result in fire or explosion.

4. The data in this curve is provided for design reference only. Final component selection and the matching of short-circuit protection fuses must be based on actual verification/testing.

Wiring diagram

ASFHB1000

External dimensions (mm)

ASFHB1000/口-口HA-CCA

ASFHB1000

Note: Undimensioned tolerances for product outline dimensions:

Size (mm) <10 10~50 >50
Tolerance (mm) ±0.3 ±0.5 ±0.8

Reviews

There are no reviews yet.

Be the first to review “ASFHB1000”

Your email address will not be published. Required fields are marked *

Get custom pricing and engineering support for your industrial automation needs.

  • OEM / ODM Customization
  • Factory Direct Pricing
  • Global Technical Support
Contact Asiaon Electric
Client Client Client
500+
Trusted by global industrial clients
Custom Engineering Support