Product Overview
AS41F Industrial Relay is a relay documented with a 1H、1Z contact form, a rated load of 6A 250VAC/30VDC, AgSnO₂ AgNi contact material.
Key Features
● 5mm thickness
● Rated load 6A
● Surge voltage up to 4KV
Technical Specifications
| Specifications | ||
| Contact | Contact Form | 1H、1Z |
| Rated Load | 6A 250VAC/30VDC | |
| Electrical/Mechanical Life | ≥100000times/10000000times | |
| Initial Contact Resistance | ≤100mΩ (1A 6VDC) | |
| Contact Material | AgSnO₂ AgNi | |
| Characteristics | Insulation Resistance | ≥1000MΩ (500VDC) |
| Dielectric Strength | Between open contacts≥1000VAC/1min | |
| Between contact and coil≥4000VAC/1min | ||
| Operate/Release Time | ≤8ms/8ms | |
| Terminal Type | Plug in/PCB | |
| Coil | Operating Power DC | 0.17W(48、60VDC 0.21W) |
DC Coil Data
| Rated Voltage (VDC) | Pickup Voltage (VDC) | Dropout Voltage (VDC) | Coil Resistance (Ω±10%) |
| 5 | 3.75 | 0.25 | 147 |
| 6 | 4.5 | 0.3 | 212 |
| 9 | 6.75 | 0.45 | 476 |
| 12 | 9 | 0.6 | 848 |
| 18 | 13.5 | 0.9 | 1906 |
| 24 | 18 | 1.2 | 3390 |
| 48 | 36 | 2.4 | 10600 |
| 60 | 45 | 3 | 16600 |
Technical Data and Drawings
Ordering Information

Dimensions (mm)

Wiring Diagram

Frequently Asked Questions
What contact material is specified?
The specified contact material is AgSnO₂ AgNi.
What insulation resistance is specified?
The specified insulation resistance is ≥1000MΩ (500VDC).
What operate and release time is listed?
The listed operate/release time is ≤8ms/8ms.




Reviews